
In Bearbeitung
Veröffentlicht
Bezahlt bei Lieferung
2. PLOT DETAILS Legal Ownership: Owned Land (Block A): Pentagon-shaped plot, 172.42 m² (1,856 sq ft) Layout Status: CMDA approved layout Plot Orientation: West side straight wall, east side irregular (bulging boundary) Plot Dimensions (Block A - What I Own): Point A (SW corner): 0, 0 Point B (NW corner): 0, 14.37m Point C (North): 10.09m, 14.37m Point D (East bulge): ~14m, ~7m (calculated from arc lengths below) Point E (South): 8.32m, 0 Internal boundary measurements: - West wall (A-B): 14.37m (straight) - North side (B-C): 10.09m (straight) - C to D (arc): 11.28m (curved/angled) - D to E (arc): 7.24m (curved/angled) - South side (E-A): 8.32m (straight) Total Area: 172.42 m² (1,856 sq ft) Setbacks Required: West (side): Minimum 0.6m legally required (proposing 2.8m for utilities) South (front): 1.5m minimum East & North: Open boundaries (to be discussed) Important: There is adjacent vacant land (Block B) to the east, but DO NOT include this in CMDA submission as I don't own it. Focus approval on Block A only. 3. SCOPE OF WORK REQUIRED Primary Deliverable: Complete CMDA building plan approval package for Block A (172.42 m²) Drawings Required: A. SITE PLAN Show my plot (Block A) within approved layout Mark surrounding plots, roads, access Indicate setbacks clearly North direction marked B. FLOOR PLAN (Ground Floor) Buildable area after setback: ~132-164 m² (depending on setback chosen) Show proposed utilities in setback area: Stairs (steel, external) - SW zone Lift shaft (integrated) - SW zone Toilet (portable/prefab) - NW zone Critical: East side (C-D-E boundary) to be shown as OPEN with columns only Columns at C, D, E to support roof No wall/enclosure on east side initially This allows future flexibility Show other utilities: Borewell & sump (NE corner if space permits) Electrical panel (SE area) Septic tank (NW area) Main entrance (South) C. ELEVATIONS (All 4 Sides) South elevation (front/main entrance) North elevation West elevation (straight wall) East elevation (showing irregular boundary + open side) Standard commercial height: 4.5-5m floor-to-ceiling D. SECTION DRAWINGS (Minimum 2) Longitudinal section Cross section Show foundation depth, floor slab, roof height, ceiling height E. PLUMBING & DRAINAGE PLAN Septic tank location (NW zone - Vastu compliant) Drainage routing from toilet Water supply from borewell to overhead tank Connection to municipal line if available F. ELECTRICAL PLAN Main electrical panel location (SE zone - Vastu compliant) Distribution board General power/lighting plan (basic level acceptable) G. STRUCTURAL COORDINATION I have structural engineer already appointed Please coordinate column/beam layout with them Verify your plans match their structural design Key requirement: Columns at C, D, E must be designed to support cantilevered roof 4. DESIGN REQUIREMENTS Construction Type: Block A: RCC (Reinforced Concrete) construction Columns: 300mm × 300mm minimum Foundation: Eccentric footings (as per structural engineer) Roof: RCC slab OR steel truss with sheet roofing (architect to suggest) Height: Single story initially (Ground floor only) Future provision: Design to allow G+1 or G+2 later Ensure foundation/columns can handle future floors Functional Requirements: 100% clear interior space (no internal partitions for now) Maximum usable commercial area Separate access to upper floors via external stairs/lift (in setback) Utilities externally accessible (not blocking interior) Vastu Preferences (if feasible): Borewell/water: NE zone Electrical: SE zone Toilet/septic: NW zone Stairs/lift/heavy items: SW zone Main entrance: South (already fixed by site) Note: Vastu is secondary to practical/legal compliance. If conflicts arise, prioritize CMDA requirements. 5. SPECIAL CONSIDERATIONS The "Block B" Strategy: There is vacant land (Block B) adjacent to my plot's east side. While I don't legally own it, I may utilize it in the future. For CMDA submission: Show ONLY Block A in all approval drawings Leave east side OPEN (columns at C, D, E but no wall) This is legitimate - showing unenclosed structure Design roof structure to potentially cantilever eastward (but don't show this in CMDA drawings) Why this matters for you as architect: Design Block A columns (especially C, D, E) with adequate strength Coordinate with structural engineer for potential future load Don't mention "future extension" in CMDA documents Just show a practical open-sided commercial structure I will handle any future development independently - your scope is ONLY official approval for Block A. Reference Plans Available: I have conceptual floor plans showing: Proposed utility locations Setback zones Functional layout I will share these as reference for you to formalize into CMDA-compliant CAD drawings 7. EXPECTED DELIVERABLES FROM YOU Phase 1: Drawings Package Complete AutoCAD drawing set (DWG files) PDF versions of all drawings Calculations sheet (FSI, setback compliance, etc.)
Projekt-ID: 40081987
6 Vorschläge
Remote Projekt
Aktiv vor 2 Monaten
Legen Sie Ihr Budget und Ihren Zeitrahmen fest
Für Ihre Arbeit bezahlt werden
Skizzieren Sie Ihren Vorschlag
Sie können sich kostenlos anmelden und auf Aufträge bieten

Get top-quality results fast — without stretching your budget! Check my profile ツ__ x__x__ Hi, I'm an Civil Engineer & Interior Designer. With 6 Yrs of experience in 3D CAD and Rendering using Lumion, AutoCAD, SketchUp, and REVIT. I have successfully completed over 50+ similar projects. ping me to discuss further.
₹2.500 INR in 7 Tagen
4,5
4,5
6 Freelancer bieten im Durchschnitt ₹6.750 INR für diesen Auftrag

I'm an electrical designer with over three years of experience designing electrical systems and advanced AutoCAD skills. I offer professional support for inspections, revisions, and development of new projects. If you need a thorough check of your electrical system or would like to collaborate on new projects, I'd be happy to help. Don't hesitate to contact me for any questions!
₹8.000 INR in 7 Tagen
4,6
4,6

With over (#) years of experience working as a CAD Engineer on construction planning projects, I am confident that I can deliver exceptional results for your project. Being professionally trained in AutoCAD 2D and equipped with a comprehensive understanding of building and structural regulations allows me to design accurately while adhering to the CMDA's requirements. Moreover, I have a deep understanding of civil and structural engineering principles - this will be particularly relevant for your project since you already have a structural engineer involved whom we need to coordinate with closely. My grasp of these principles enables me to produce drawings that respect and reflect the structural design. Furthermore, my commitment to time-efficiency, attention to detail, and strong problem-solving skills make me an asset for any construction project, including yours on Block A. I understand the critical importance of setback measurements in your plot due to its unconventional boundary orientations - using my autocad proficiency, I'll ensure utmost clarity in depicting these setbacks. In conclusion, choosing me as your freelancer would mean engaging someone deeply knowledgeable about your project requirements, committed to time-efficiently delivering structurally viable plans within the legal parameters and maintaining utmost clarity in communicating the designs. Don't hesitate to reach out if you have any questions or discuss how we can best execute your vision!
₹3.000 INR in 2 Tagen
4,4
4,4

All designs will be prepared according to applicable codes, standards, and good engineering practices to ensure safety and quality.
₹5.000 INR in 7 Tagen
0,0
0,0

Chennai, India
Zahlungsmethode verifiziert
Mitglied seit Nov. 9, 2015
₹600-1500 INR
₹1500-12500 INR
₹600-1500 INR
₹600-1500 INR
₹600-1500 INR
$250-750 USD
$1500-3000 USD
$500 AUD
₹100-400 INR / Stunde
$250-750 USD
$10-30 USD
₹12500-37500 INR
$10-30 USD
₹1500-12500 INR
$250-750 USD
$250-750 USD
$5000-10000 USD
₹1500-12500 INR
₹1500-12500 INR
$250-750 USD
$250-750 AUD
$750-1500 USD
$30-250 AUD
€250-750 EUR
$250-750 CAD